Jacketed Glass Reactor
Glass reactor is popular as physical or chemical reaction vessel,through reaction vessel structure design and parameter configuration to achieve the process requirement of heating, evaporation, cooling and low-high-speed mixing function.
For research, glass reaction vessel could do new materials synthesis, mixing homogeneous reaction, extraction and purification, distillation and samples purification.
Technical parameters of TOPTION brand jacketed glass reactor:
Type | TOPT-1L | TOPT-2L | TOPT-3L | TOPT-5L | TOPT-10L |
Stir medium flange | 35 | 35 | 35 | 40 | 50 |
Liquid material inflow | 24# 0.25L | 24# 0.25L | 24# 0.25L | 24# 1L | 34# 1L |
Condenser | 24# | 24# | 24# | 24# | 34# |
Temp. measure | 14# | 14# | 14# | 19# | DN15 |
Multi function valve | | | | 24# | DN25 |
Solid charging port | | | | | DN80 |
Stirring paddle | ¢7mm Anchor type | ¢7mm Anchor type | ¢7mm Anchor type | ¢10mm single layer two blade paddle type | ¢16mm single layer three blade paddle type |
Reactor lid flange (mm) | 150 | 150 | 150 | 180 | 265 |
Inner diameter of reactor body (mm) | 113 | 135 | 150 | 180 | 230 |
External diameter (mm) | 150 | 180 | 200 | 230 | 290 |
Reactor body height (mm) | 250 | 280 | 300 | 400 | 450 |
Power (w) | 40 | 40 | 40 | 60 | 120 |
Rotate speed (rpm) | 50-800 | 50-800 | 50-800 | 50-600 | 50-600 |
Related heating and cooling circulators of jacketed glass reactor:
1.Double layer glass reactor (charging material in reaction vessel, add heat conduction or refrigerating medium in jacketed layer).
2. High temperature: could equip heating device based on different temperature requirement, TOPTION UC series and TG series could help you achieve RT-180℃ and RT-300℃.
3. Low temperature: temperature range below room temp., the lowest temperature could reach -80℃, could equip TOPTION LX series cooling device according to different temp.
Requirement. For laboratory double layer glass reactor 1L, 2L, 3L,5L, if your operation temperature is between RT and -40℃, you also could choose DL series cooling device. Contact info@toption-china.com for detail configuration suggestion, 24h/7days online service.
4. High & low temperature device, HR series is standard configuration, but if you need to alternate and convert between different temperature range, SUNDI series temperature control system.
5. Vacuum pump is available, to help your achieve vacuum condition, if you need to set and control temperature accurately, TOPTION brand VC-100 vacuum controller is available.

- TOPTION vacuum pump for jacketed glass reactor
Our customer’s case